Skip to main content

A service of Otto Zickwolff GmbH, Germany

Dimension tables & drawingsVisit our shop →

Dimension table · Gaskets

Flat gaskets to DIN 2690 (withdrawn): dimension table for existing plant

DIN 2690 set out the dimensions of flat gaskets for flanges with a flat sealing face. The inside diameter d1 follows the nominal size DN, and the outside diameter d2 additionally follows the pressure rating. The table covers DN 4 to DN 1400 and is fully verified in the DN 4–500 range against the manufacturer's dimension table KLINGER Information 70.1.1.

Standard
DIN 2690
Status
Withdrawn, replaced by EN 1514-1
Type
Flat sealing face
Scope
PN 1 – PN 40
Nominal sizes
DN 4 – DN 1400

Note on standard status: DIN 2690 is withdrawn and has been replaced by EN 1514-1. The dimensions below serve solely for identification and the maintenance of older plant and existing stock. For new designs, the contractually agreed, currently valid flange and gasket standards prevail – for flanges to EN 1092-1 generally the relevant parts of the EN 1514 series – along with the operating conditions and manufacturer specifications. In trade, orders to DIN 2690 are still placed in some cases – we supply the matching part.

Asbestos-free fibre-material flat gasket in ring form for the raised face
Flat gasket from the Zickwolff range: ring form for the raised face, inside Ø d1 by DN, outside Ø d2 by pressure rating. Image: Zickwolff shop

Good to know when cross-checking existing plant: the dimensions of DIN 2690 have largely been absorbed into the current EN 1514-1 (form IBC – ring inside the bolt circle); for a few nominal sizes the EN values differ by a few millimetres. The current dimensions are set out on our page Flat gaskets to EN 1514-1; for guidance on gasket forms and materials see the gaskets overview.

Tip: use Ctrl/Cmd + F to jump straight to the nominal size you need.

The standard names dimensions. What is listed here, we carry – from stock or to order; how quickly a size is available we clarify on request.

Inside Ø d1 and outside Ø d2 to DIN 2690, all dimensions in millimetres – availability: from stock or to order
DN Inside Ø d1 PN 6 PN 10 PN 16 PN 25 PN 40
46–––30–
6102838383838
8143343434343
10183845454545
15224350505050
20285360606060
25356370707070
32437582828282
40498592929292
506195107107107107
6577115127127127127
8090132142142142142
100115152162162168168
125141182192192195195
150169207218218225225
(175)195237248248255267
200220262273273285292
250274318328330342353
300325373378385402418
350368423438445458475
400420473490497515547
(450)470528540557565572
500520578595618625628
600620680695735730745
700720785810805830850
800820890915910940970
9009209901015101010401080
1000102010901120112511501190
1200122013051340134013601395
1400142015201545154015751615

"–" means: not documented in the source. Values in brackets (e.g. "(175)") mark less commonly used nominal sizes. For PN 1 and PN 2.5, use the PN 6 dimensions, except for DN 1200 (outside Ø 1290 mm) and DN 1400 (outside Ø 1490 mm). DN 60 is a special nominal size provided only for cast-iron flanges. Typical ordering information: "Gasket DIN 2690, DN 65, PN 40, material, s = 1.5 mm" – for new designs correspondingly "Gasket EN 1514-1, form IBC, …".

Find the matching gasket directly

We carry flat gaskets matched to flanges and bolting from stock – cut-to-size and special materials on request. The overview shows which material suits which medium and temperature.

Frequently asked questions

What are the dimensions of a DIN 2690 flat gasket for DN 100 PN 16?

The dimension table on this page gives inside and outside diameter of the flange gasket per DN and PN to DIN 2690; thickness depends on material and installation.

Your inquiry to Zickwolff

Send us what you have – designation, standard, quantity, date. We will clarify the rest with you.

← Back to the gaskets overview

How this data is compiled. This page does not reproduce a standard. It shows the dimensions you need for an enquiry, an order and installation – for sizes we supply, checked against manufacturers’ and suppliers’ documentation and against our own product data. What you see here is what the market supplies, checked against the standard – or calculated by us. How we select our sources and keep them up to date: About this knowledge.

Technical basis: DIN 2690 (withdrawn; dimensions for identification and maintenance of existing plant). Dimension data DN 4–500 fully verified against the manufacturer's dimension table KLINGER Information 70.1.1 (flat gaskets to EN 1514-1 and DIN 2690); DN 600–1400 from a distributor dimension table with a documented QA correction for DN 800/PN 6. All information without guarantee – for new designs the current standard texts and the manufacturer's technical data sheets always prevail. Selection of values follows our delivery and stock programme; compiled from our own inventory management and long-standing trading practice, cross-checked against publicly available manufacturer data. This table does not replace the standard text – the currently valid standard always prevails.